Batteries
Find the RAID controller battery for your array by its family: PowerVault MD32xx, MD34xx, MD36xx and MD38xx controllers and EqualLogic PS4210, PS6210 and PS6610 control modules each take batteries of their own. Dell's battery for those MD3 controllers is the D668J. A weak MD3 battery changes how the array writes: Dell's MD3400 manual says the controller flushes its cache and runs every virtual disk in write-through until the battery is replaced. HPE's DL380 Gen10 QuickSpecs pair its performance RAID controllers with the HPE Smart Storage Battery; see also PowerVault controllers, EqualLogic controllers and server batteries.
- Dell D668J PV MD32XX MD34XX MD36XX MD38XX RAID Controller BatteryAvailability: Available by QuoteManufacturer: Dell Condition: Refurbished 1 Year WarrantyRequest PricingOut of stock
- Dell 10DXV EQL PS4210 PS6210 PS6610 Controller Smart BatteryAvailability: Available by QuoteManufacturer: Dell Condition: Refurbished 1 Year WarrantyRequest PricingOut of stock
- Dell FK6YW EQL PS4210 PS6210 PS6610 Controller Smart BatteryAvailability: Available by QuoteManufacturer: Dell Condition: Refurbished 1 Year WarrantyRequest PricingOut of stock
- HP 878640-001 12W Smart Storage BatteryAvailability: Available by QuoteManufacturer: HPE Condition: Refurbished 1 Year WarrantyRequest PricingOut of stock
- APC SURT6000XLT 6000VA Battery Backup UPSAvailability: Available by QuoteManufacturer: APC Condition: Refurbished 1 Year WarrantyRequest PricingOut of stock
What a controller battery protects
A controller battery keeps cached writes safe through a power loss, and Dell's manuals describe a different job for it in each array family.
| Array family | What the battery does | Service note in the manual |
|---|---|---|
| PowerVault MD3400-class (MD3) | A battery backup unit in each RAID controller module powers it in an outage so the mirrored cache can be offloaded to non-volatile memory | Write-back caching resumes once the replacement battery is in |
| EqualLogic PS6210 (Type 15 control module) | An integral battery runs the cache-to-flash feature of the control module | Replace it when Group Manager reports a battery failure, with the module in secondary mode |
| Compellent SC5020 and SC7020 | If power fails, a battery backup unit in each storage controller keeps it running until the mirrored write cache has been copied to an SSD inside the controller | Replace the unit if it begins to fail |
After an EqualLogic array has been shipped with its batteries in ship mode, Dell allows up to 20 minutes at first power-up for them to recharge to 100 percent.