The Dell PowerSwitch N3224T-ON is a 1RU campus access switch with 24 auto-sensing 10/100/1000Mb RJ45 ports, four 10GbE SFP+ uplinks and two 100GbE QSFP28 rear stacking ports, on a 528 Gbps non-blocking fabric forwarding at 733 Mpps.
It is the 24-port member of Dell's current campus generation, and its distinguishing feature is that halving the port count costs you nothing structural: it keeps the full 400 Gbps stacking architecture, the full Advanced Layer 3 stack and the dual hot-swappable power supplies of its 48-port siblings.
The 24-port switch that is not a cut-down switch
Most vendors treat the 24-port model in a campus family as the budget variant - fewer ports, and quietly fewer features: reduced stacking, a fixed power supply, a smaller routing table, a licence tier that withholds BGP. That is not what happens here.
The N3224T-ON carries the same two rear 100GbE QSFP28 stacking ports and the same 400 Gbps of stacking bandwidth as the 48-port models, and joins the same twelve-unit stack under a single IP address. It carries the same routing scale: 1,024 static and 8,158 dynamic IPv4 routes, 4,094 VLANs, 6,144 ARP entries, 16-way ECMP across 1,024 groups. It runs the same Advanced Layer 3 - BGP, VRF-lite, BFD, PIM, OSPFv2/v3 - with no licence tier gating it. It takes the same dual hot-swappable 80PLUS Platinum power supplies.
What you give up is 24 access ports and some forwarding headroom: 528 Gbps of fabric and 733 Mpps against the 48-port model's 576 Gbps and 800 Mpps. Both are non-blocking for their own port count, so the difference is capacity, not behaviour.
Where a 24-port model is the right answer
Three situations, mostly.
The small closet. A floor with thirty drops does not need a 48-port switch, and buying one anyway means paying for and powering 18 ports that will never see a cable. At 201W maximum draw and 686 BTU/hr - the lowest in the family - the N3224T-ON is also the easiest model to put in a closet with marginal ventilation.
The branch site. Remote offices need the same feature set as head office and a fraction of the ports. Because this switch is not feature-reduced, a branch can run the identical configuration template, the identical VRF layout and the identical 802.1X policy as the main campus. USB auto-configuration matters here too: you deploy a switch by inserting a USB key rather than by sending someone who knows the CLI.
The stack you will grow. Because it stacks with the rest of the family at 400 Gbps, starting with a 24-port unit is not a dead end. Add a N3248TE-ON to the stack when the floor fills up and the two present as one logical switch with one configuration and one IP address.
Both airflow directions
The N3224T-ON is one of only three models in the family - with the N3248TE-ON and the N3248X-ON - for which Dell offers the fan module in both directions. It can therefore be built as I/O Panel to PSU (standard) or PSU to I/O Panel (reverse).
The choice follows the rack, not preference. A switch racked with its ports toward the cold aisle takes standard airflow; one racked with its ports toward the hot aisle - common where switch ports sit on the same side as server NICs to shorten cable runs - takes reverse, or it recirculates its own exhaust. Power supplies and fan modules are direction-specific parts, so this is decided at build time. Tell us which way your row faces when you request a quote.
OS6, ONIE and licensing on the used market
The switch runs Dell EMC Networking OS6, the campus operating system common to the whole N-series - the same CLI, web GUI, SNMP behaviour and Dell OpenManage Network Manager integration you already use elsewhere in the estate. It is an ONIE platform, so an alternative network operating system can be installed if that is your standard.
A Dell software entitlement is bound to the unit's service tag and to a Dell account and does not automatically transfer on the secondary market. A refurbished unit may arrive with a working image installed and without an active entitlement or a support contract. We do not promise a transferred Dell licence, a software subscription or a support contract with a refurbished switch. Tell us what you intend to run and we will confirm the state of a specific unit before it ships.
Common questions
- Does it stack with the 48-port models?
- The family is designed to stack over the rear 100GbE ports at 400 Gbps, up to twelve units under one IP address, and Dell quotes mixed stack densities across 1/2.5/5/10GbE and 25GbE port types. Mixed-model stacking depends on the OS version and the features you need - confirm the exact combination with us before ordering.
- Does it do PoE?
- No. The 24-port PoE models in this family are the N3224P-ON at 802.3at 30W and the N3224PX-ON at 802.3bt up to 90W; neither is currently listed here. For 48-port PoE, see the N3248PXE-ON, or the entry-level N1148P-ON.
- Is there a fibre version?
- Dell builds one - the N3224F-ON, with 24x 1G SFP instead of copper - but it is not currently listed here. Ask us if you need it.
- Are the two 100GbE ports usable as uplinks?
- Dell describes them as integrated rear stacking ports. Plan uplinks around the four front-panel 10GbE SFP+ ports.
Choosing within the N3200-ON and N2200-ON campus families
| Model | Access ports | Uplinks | Fabric | Where it fits |
|---|---|---|---|---|
| N3224T-ON (this switch) | 24x 1GbE RJ45 | 4x 10GbE SFP+ | 528 Gbps | Small closets, branch sites, the start of a stack |
| N3248TE-ON | 48x 1GbE RJ45 | 4x 10GbE SFP+ | 576 Gbps | The mainstream 48-port 1GbE closet |
| N3248X-ON | 48x multigig 1/2.5/5/10GbE | 4x 25GbE SFP28 | 1560 Gbps | Multigig copper for self-powered endpoints |
| N3248PXE-ON | 48x multigig 1/2.5/5/10GbE, 802.3bt 90W PoE | 4x 25GbE SFP28 | 1560 Gbps | Wi-Fi 6E and Wi-Fi 7 access points |
| N2248X-ON | 48x multigig 1/2.5GbE | 4x 25GbE SFP28 | 600 Gbps | Multigig access where 2.5G is enough |
Availability, condition and how to buy
This model is supplied to order. Availability, airflow direction, power-supply count and optics loadout are confirmed at quotation, so use the quote request on this page and tell us the configuration you need.
Every unit is refurbished, professionally reconditioned, powered up, inspected and functionally tested before it ships, and it ships with warranty coverage. If you need a specific firmware state or matched units for a stack, say so with your request.
Specifications
| Model | N3224T-ON |
|---|---|
| Ports | 24x RJ45 10/100/1000Mb auto-sensing, 4x 10GbE SFP+, 2x 100GbE QSFP28 (rear stacking) |
| Uplinks | 4x 10GbE SFP+; 2x 100GbE QSFP28 rear stacking ports |
| Interface / Media | RJ45 10/100/1000BASE-T / SFP+ (10GbE) / QSFP28 (100GbE stacking) |
| Connector Types | RJ45, SFP+, QSFP28 |
| Data Rates | 1GbE access (RJ45); 10GbE (SFP+); 100GbE (QSFP28 stacking) |
| Integrated 10GbE SFP+ | 4x 10GbE SFP+ |
| Switch Fabric Capacity | 528 Gbps (full duplex) |
| Forwarding Performance | 733 Mpps |
| CPU Memory | 4GB |
| Onboard Storage | 8GB SSD |
| Packet Buffer Memory | 8MB |
| Rack Units | 1U |
| Form-Factor | 1RU |
| Dimensions | 1.71 x 17.09 x 15.75 in (H x W x D); power supply / fan tray handle adds 1.18 in |
| Weight | 13.8 lbs |
| Airflow Direction | I/O Panel to PSU (standard) and PSU to I/O Panel (reverse) builds both offered |
| Power Supplies | 550W AC hot-swappable internal power supply, 80PLUS Platinum; second 550W AC or DC supply optional for 1+1 redundancy |
| Power Redundancy | Yes - optional second 550W hot-swappable PSU (1+1) |
| Power Supply Efficiency | 87% or better in all operating modes (80PLUS Platinum) |
| Maximum Power Consumption | 201W maximum |
| Maximum Thermal Output | 686 BTU/hr |
| Fan Modules | Redundant variable-speed fan module; direction-specific. This is one of only three models in the family (with N3248TE-ON and N3248X-ON) for which Dell offers the PSU-to-I/O fan module |
| Power Cords | C13 to NEMA 5-15, 3M; C13 to C14, 2M |
| Operating System | Dell EMC Networking OS6 (pre-installed); ONIE supports installation of alternative network operating systems |
| Switching / Routing | Layer 2 and Layer 3 Advanced IPv4/IPv6 - BGP, VRF-lite, BFD, PIM-SM/DM/SSM, IGMP/MLD, RIPv1/v2, OSPFv2/v3 |
| Line-Rate | Layer 2 switching and Layer 3 routing both non-blocking |
| Switching Engine | Store and forward |
| Stackable | Yes - 400Gbps stacking bandwidth over 2x 100GbE QSFP28 rear stacking ports; up to 12 switches managed from a single IP address |
| Stacking Bandwidth | 400 Gbps (full duplex) |
| Maximum Stack Size | 12 switches from a single IP address |
| Series Stack Density | Up to 624 1/2.5/5/10GbE/25GbE ports across an N3200-ON stack |
| Multi-Chassis | Multichassis Link Aggregation (MLAG) for active/active loop-free redundancy without spanning tree |
| MAC Addresses | 32K |
| VLANs | 4,094 |
| IPv4 Scale | 1,024 static / 8,158 dynamic IPv4 routes; 6,144 ARP entries; 8,158 OSPF routing interfaces |
| IPv6 Scale | 1,024 static / 4,096 dynamic IPv6 routes; 2,560 NDP entries |
| VLAN Routing Interfaces | 128 |
| RIP Routing Interfaces | 512 |
| ECMP | 16 next hops per route; 1,024 ECMP groups |
| Multicast Forwarding Entries | 1,536 (IPv4), 512 (IPv6) |
| Link Aggregation | 128 LAG groups, 144 dynamic ports per stack, 8 member ports per LAG |
| QoS | 8 priority queues per port; adjustable WRR and strict queue scheduling; DiffServ, srTCM, trTCM, Red/WRED |
| Jumbo Frames | MTU 9,216 bytes |
| ACL Scale | Max 100 ACLs; 3,914 rules system-wide; 1,023 rules per ACL; IPv4 1,023 ingress / 511 egress; IPv6 1,021 ingress / 509 egress; 24 VLAN interfaces with ACLs applied |
| Overlay | VXLAN support in hardware only (usable when enabled by an ON partner network operating system) |
| PoE | No |
| Management | 10/100/1000BASE-T out-of-band management port, USB Type A, MicroUSB Type B console, RJ45 console with RS232; CLI, embedded web GUI, SNMP, Telnet, serial; AAA authorization, TACACS+ accounting, RADIUS |
| Security | 802.1X network access control with Auto VLAN, MAC Authentication Bypass, Captive Portal, authentication tiering, private VLAN extensions and Private VLAN Edge |
| Zero-Touch Provisioning | Open Network Install Environment (ONIE); USB auto-configuration from a USB flash drive |
| Energy Efficiency | 802.3az Energy-Efficient Ethernet with per-port settings; lower-power PHYs on inactive ports and idle links |
| IEEE Compliance | 802.1AB, 802.1D, 802.1p, 802.1Q, 802.1S, 802.1v, 802.1W, 802.1X, 802.2, 802.3, 802.3ab, 802.3ac, 802.3ad, 802.3ae, 802.3AX, 802.3az, 802.3bz (1G/2.5G/5G/10G), 802.3u, 802.3x, 802.3z; ANSI LLDP-MED (TIA-1057) |
| Operating Temperature | 32 to 113 F (0 to 45 C) |
| Operating Relative Humidity | 95% |
| Storage Temperature | -40 to 158 F (-40 to 70 C) |
| Storage Relative Humidity | 95% |
| Fresh Air | Dell Fresh Air compliant for operation up to 113 F (45 C) |
| Rack Mounting | 2-post rack mounting kit |
| Regulatory | ACMA RCA Class A; ICES Class A and cUL; CCC Class A and NAL; CE Class A; VCCI Class A; FCC Class A, NRTL UL, FDA 21 CFR 1040.10 and 1040.11; EAC; GS mark |
| Compliance | RoHS, EU WEEE, EU Battery Directive, REACH; N-Series products carry the features needed to support a PCI compliant network topology |