Dell PowerSwitch Z9432F-ON 400GbE Switch

Total Price:
Request Pricing

What to Expect from Enterasource

Why choose Enterasource?

At Enterasource, we pride ourselves on delivering top-notch service to our valued customers. Here are just a few of the benefits you can expect when choosing us for your IT needs

Complimentary ground shipping on orders over $50 throughout the contiguous United States (exclusions apply to Hawaii and Alaska).

Efficient same-day shipping for in-stock orders placed before 3PM PST.

Rapid one business day quote response time.

Industry-leading next business day parts
replacement warranties to ensure your equipment stays up and running.

Our commitment to exceptional customer service and timely delivery make us the ideal choice for all your IT hardware needs. Choose Enterasource for a hassle-free experience and the highest quality product on the market.

Dell PowerSwitch Z9432F-ON 400GbE Switch
Manufacturer:
Dell
Condition:
Refurbished
Availability:
Ships in 5-7 Business Days
Too many options? We are happy to help you configure.
Ask a question
Requires 2 for proper configuration
Qty:
Requires 2 for proper configuration
Qty:
Qty:
Qty:
Qty:
Qty:

Description

The Dell PowerSwitch Z9432F-ON is a 1RU aggregation switch with 32 ports of 400GbE in QSFP56-DD form factor plus two 10GbE SFP+ ports, a 25.6 Tbps full-duplex switch fabric, 5.2 Bpps of forwarding capacity, a 132MB packet buffer and sub-850 ns latency. This unit is the reverse-airflow build.

Dell lists the Z9432F-ON under both its AI switches and its data centre switches categories, and that dual classification is the honest description of what this box is: a general-purpose 400GbE aggregation switch that happens to have the buffer and the RDMA support that AI and machine-learning fabrics demand.

Thirty-two 400GbE ports in one rack unit

The headline configuration is 32 ports of 400GbE. Dell also publishes the two densities that matter more in practice: up to 128 ports of 100GbE, or up to 144 ports of 10, 25 or 50GbE, both reached with breakout cables. One rack unit, and a choice between a 400GbE spine and a 128-port 100GbE aggregation layer.

Every 400GbE port is multi-rate. Dell states it explicitly: the 400GbE ports support 10/25/40/50/100GbE, and 40GbE ports support 10 and 40GbE. That is what makes this switch buildable into an existing estate rather than only into a greenfield one - the same cage that will carry a 400GbE link next year can carry a 100GbE link today.

Two 10GbE SFP+ ports sit alongside, useful for management uplinks or out-of-band paths that should not consume a 400GbE cage.

The buffer is the specification that matters

At 132MB, the packet buffer on this switch is several times what the previous 100GbE generation carried, and it is the single most consequential number on the sheet. Aggregation points are where incast happens - many senders converging on one receiver, all at line rate - and buffer is what absorbs it. A switch with a large fabric and a small buffer will drop under exactly the traffic pattern that aggregation exists to handle.

That is also why this design shows up in AI fabric conversations. Distributed training traffic is synchronised and bursty by construction: every node finishes its step at roughly the same moment and every node transmits at roughly the same moment. Routable RoCE support lets that traffic run RDMA over a routed fabric, and Data Center Bridging - priority flow control under 802.1Qbb, enhanced transmission selection under 802.1Qaz, DCBx and iSCSI TLV - gives it the lossless treatment it needs. Buffer, RoCE and DCB together are why Dell files this switch under AI as well as data centre.

Latency is sub-850 ns and the fabric is 25.6 Tbps full duplex, delivering line-rate performance under full load. Table scale runs to 156K MAC addresses, up to 400K IPv4 routes with ALPM, 300K IPv6 routes and 4K Layer 2 VLANs, with 64 MSTP instances.

QSFP56-DD, and what the cage actually is

QSFP56-DD is a double-density QSFP cage: eight lanes of 50G PAM4 rather than the four lanes of a QSFP28. That is where 400GbE comes from, and it is also why the same cage breaks out so flexibly - eight lanes can be divided several ways.

Two practical consequences. First, optics for these ports are 400GbE-class modules; a QSFP28 100GbE module is a different cage generation and does not simply drop in as a 400GbE link. Second, optics power is a real constraint at this density: Dell budgets up to 15W per module across all QSFP56-DD ports, with an allowance for four ports at 20W when the switch is running in the I/O-panel-to-PSU airflow direction. If you are planning long-reach coherent modules, check their power draw against that budget before you order.

Airflow: standard and reverse builds

This listing is the model page for the Z9432F-ON and covers both airflow builds. Select the direction under the Airflow option: direction is set by the power supplies and fan modules fitted, so it is a build-time choice, and PSUs and fans must both face the same way.

The reverse-airflow unit: air is drawn in at the power-supply face and exhausted at the I/O panel. That is the direction you want when the switch is racked with its ports facing the hot aisle - the common layout, because it puts the switch ports on the same side as the server NICs. Power supplies and fan modules are direction-specific parts, so the whole chassis runs one direction and changing it later means replacing all of them. Seven fans provide 6+1 redundancy.

The power detail worth reading twice is Dell's own footnote on redundancy. The switch takes two hot-swappable power supplies at 1+1 redundancy - except when running on lowline power. A 100-127 VAC supply is explicitly a non-redundant solution on this model. If your rack is on 120V and you were counting on PSU redundancy, that assumption does not hold; plan for 200-240 VAC. Maximum consumption is 1404W with a 900W typical figure.

SmartFabric OS10, SONiC, and buying it second-hand

The "-ON" suffix is Dell's open networking designation. The switch supports the open source Open Network Install Environment for zero-touch installation of Dell SmartFabric OS10, Enterprise SONiC Distribution by Dell Technologies, or an alternative ONIE-compatible network operating system.

On the secondary market that separation is the whole point. The hardware you buy is 32 ports of 400GbE silicon, an 8-core Denverton control plane with 32GB of DDR4 ECC and a programmable NPU pipeline. The operating system is a separate decision made at install time, not a licence state inherited from a previous owner. Expect a unit to need an OS install on arrival - a switch sitting at the ONIE prompt is in the state Dell designed.

Rack mounting uses Dell's accelerated mounting kits. Note that the Z9432F-ON does not take the universal S-series rail; it shares a dedicated 1U ReadyRails kit with the S5448F-ON.

Where it sits in Dell's 400GbE line

The Z9432F-ON is the entry point to 400GbE in Dell's fixed-format range, and it is the 1RU one. The Z9664F-ON doubles the port count to 64 x 400GbE and the fabric to 51.2 Tbps, in 2RU. The Z9864F-ON moves to 800GbE on OSFP112 cages and is the switch Dell positions for large AI training clusters. Below all three, the Z9264F-ON and Z9100-ON hold the 100GbE tier.

Every unit is professionally reconditioned, fully tested and shipped with warranty. This model is quote-only - tell us the airflow direction, optics and quantity you need and a specialist will come back to you with availability.

Specifications

ModelZ9432F-ON
Form-Factor1RU high-density 100/400GbE aggregation switch
Ports32x 400GbE QSFP56-DD ports, plus 2x 10GbE SFP+
Uplinks / Downlinks2x 10GbE SFP+
InterfaceQSFP56-DD (400GbE, multi-rate 10/25/40/50/100GbE) / SFP+ (10GbE)
Connector TypeQSFP56-DD, SFP+
Data Rate400GbE native; multi-rate 10/25/40/50/100GbE on the 400GbE ports; 10GbE on SFP+
Maximum 400GbE Density32 (QSFP56-DD)
Maximum 100GbE Density128 (via breakout)
Maximum 10/25/50GbE Density144 (via breakout)
Multi-Rate Support400GbE ports support 10/25/40/50/100GbE; 40GbE ports support 10/40GbE
Throughput25.6 Tbps switch fabric capacity (full duplex)
System Capacity25.6 Tbps (full duplex), non-blocking
Forwarding Performance5.2 Bpps
Port-to-Port Latencysub 850 ns
Packet Buffer Memory132MB
CPUIntel Denverton C3758, 8 cores @ 2.2GHz
Memory32GB DDR4 ECC
NPUPipeline is programmable using NPL
RoutingLayer 2 and Layer 3 with a full complement of standards-based IPv4 and IPv6 features, including OSPF and BGP
MAC Addresses156K
IPv4 unicast/multicast routesUp to 400K IPv4 routes (ALPM); ARP table 16K standalone, 8K shared
IPv6 unicast/multicast routes300K IPv6 routes; 4K IPv6 multicast routes
Multicast Hosts1K
Number of VLANs4K (Layer 2)
MSTP Instances64
LAG Load BalancingLayer 2, IPv4 or IPv6 headers
StackableLayer 2 multipath via Virtual Link Trunking (VLT) and Routed VLT
Quality-of-Service (QoS)Data Center Bridging with priority flow control (802.1Qbb), enhanced transmission selection (802.1Qaz), DCBx and iSCSI TLV
RDMARoutable RoCE, enabling convergence of compute and storage on Active Fabric
Storage ConvergenceiSCSI and FCoE deployment including DCB converged lossless transactions
TimingTiming card PTP/1588 and Sync-E; Trusted Platform Module
Operating SystemDell SmartFabric OS10 or Enterprise SONiC Distribution by Dell Technologies; Open Network Install Environment (ONIE) for zero-touch installation of alternative network operating systems
Remote Management Protocol1x RJ45 console/management port with RS232 signaling and Micro USB-B port, 1x 10/100/1000BASE-T Ethernet management port, 1x USB 2.0 Type A storage port
Zero-Touch ProvisioningOpen Network Install Environment (ONIE)
Dimensions1.72 x 17.3 x 21.7 in (H x W x D)
Weight22.0 lbs (9.98 kg)
Rack MountingAccelerated mounting kits, reducing time and resources for rack installation
Airflow DirectionReverse - PSU to I/O panel. This is the reverse-airflow build.
Fan Modules7 hot-swappable fans per switch, 6+1 redundancy
Optics Power BudgetUp to 15W in all QSFP56-DD ports; up to 4 ports of 20W optics when in the I/O-panel-to-PSU airflow direction
Power Supply Type2x hot-swappable power supplies, AC or DC, in I/O-panel-to-PSU or PSU-to-I/O-panel airflow. 100-240 VAC 50/60 Hz; both lowline and highline AC modes supported.
Redundant Power SupplyYes - 2x hot-swappable power supplies, 1+1 redundancy except when running on lowline (100-127 VAC) power, which is non-redundant
Integrated Power SupplyNo - 2x hot-swappable modular power supply bays
Max Power Consumption1404W maximum
Power900W typical
Input Power100-240 VAC, 50/60 Hz; supports both lowline and highline AC power modes. 100-127 VAC lowline is a non-redundant power solution.
Operating Temperature32 to 113 F (0 to 45 C)
Operating Humidity5 to 90% RH, non-condensing
Storage Temperature-40 to 158 F (-40 to 70 C)
Storage Humidity5 to 95% RH, non-condensing
Fresh AirFresh air compliant to 45 C
RegulatoryUL/CSA 60950-1 2nd Edition; EN 60950-1 2nd Edition; IEC 60950-1 2nd Edition including all national deviations and group differences; EN 60825-1 and EN 60825-2 laser safety; FDA 21 CFR 1040.10 and 1040.11; EU RoHS compliant
EmissionsAS/NZS CISPR 22 Class A; ICES-003 Issue 4 Class A; EN 55022 (CISPR 22) Class A; VCCI V3/2009 Class A; FCC CFR 47 Part 15 Subpart B Class A
CertificationsAvailable with US Trade Agreements Act (TAA) compliance; USGv6 Host and Router certified; IPv6 Ready for Host and Router; UCR DoD APL (core and distribution ALSAN switch). Federal certifications are granted on an OS-specific basis.
Dell Product GroupingDell lists the Z9432F-ON under both AI switches and Data center switches
PoENo

Technical Specs

Part TypeEthernet Switch
MPNZ9432F-ON
ManufacturerDell
ConditionRefurbished
Product LinePowerSwitch Z-Series
InterfaceQSFP56-DD (400GbE, multi-rate 10/25/40/50/100GbE) / SFP+ (10GbE)
Rack Units1U
Number of Ports32
Port Specs32x 400GbE QSFP56-DD ports, plus 2x 10GbE SFP+
Port Speed400G
PoENo
Uplinks / Downlinks2x 10GbE SFP+
Memory32GB DDR4 ECC
Power Supply Type2x hot-swappable power supplies, AC or DC, in I/O-panel-to-PSU or PSU-to-I/O-panel airflow. 100-240 VAC 50/60 Hz; both lowline and highline AC modes supported.
Redundant Power SupplyYes - 2x hot-swappable power supplies, 1+1 redundancy except when running on lowline (100-127 VAC) power, which is non-redundant
Forwarding Performance5.2 Bpps
Throughput25.6 Tbps switch fabric capacity (full duplex)
System Capacity25.6 Tbps (full duplex), non-blocking
RoutingLayer 2 and Layer 3 with a full complement of standards-based IPv4 and IPv6 features, including OSPF and BGP
Data Rate400GbE native; multi-rate 10/25/40/50/100GbE on the 400GbE ports; 10GbE on SFP+
Integrated 10GbE SFP+ Dedicated Ports2x SFP+ 10GbE
Connector TypeQSFP56-DD, SFP+
Operating SystemDell SmartFabric OS10 or Enterprise SONiC Distribution by Dell Technologies; Open Network Install Environment (ONIE) for zero-touch installation of alternative network operating systems
Quality-of-Service (QoS) queues/portData Center Bridging with priority flow control (802.1Qbb), enhanced transmission selection (802.1Qaz), DCBx and iSCSI TLV
MAC Addresses156K
IPv4 unicast/multicast routesUp to 400K IPv4 routes (ALPM); ARP table 16K standalone, 8K shared
IPv6 unicast/multicast routes300K IPv6 routes; 4K IPv6 multicast routes
Number of VLANs4K (Layer 2)
Remote Management Protocol1x RJ45 console/management port with RS232 signaling and Micro USB-B port, 1x 10/100/1000BASE-T Ethernet management port, 1x USB 2.0 Type A storage port
Dimensions1.72 x 17.3 x 21.7 in (H x W x D)
Width17.3"
Depth21.7"
Height1.72"
Weight22.0 lbs
Integrated Power Supply (Not Removable)No - 2x hot-swappable modular power supply bays
Power900W typical
Max Power Consumption (Watts)1404W maximum
StackableLayer 2 multipath via Virtual Link Trunking (VLT) and Routed VLT