Dell Networking S4048T-ON 10GbE Switch

The Dell EMC Networking S4048T-ON is a high-performance, 1U rack unit switch designed for businesses seeking robust IT solutions. This managed L3 switch features 48 ports of 10GBASE-T and 6x 40Gb QSFP+ for superior connectivity. It operates on a power range of 100 - 240 VAC 50/60 Hz, ensuring reliable performance in diverse power conditions. The switch is not stackable and does not support PoE. It is designed to operate efficiently in a humidity range of 10 to 85% (RH), non-condensing. Upgrade your network with the Dell EMC Networking S4048T-ON for enhanced speed and reliability.
Total Price:
Request Pricing

What to Expect from Enterasource

Why choose Enterasource?

At Enterasource, we pride ourselves on delivering top-notch service to our valued customers. Here are just a few of the benefits you can expect when choosing us for your IT needs

Complimentary ground shipping on orders over $50 throughout the contiguous United States (exclusions apply to Hawaii and Alaska).

Efficient same-day shipping for in-stock orders placed before 3PM PST.

Rapid one business day quote response time.

Industry-leading next business day parts
replacement warranties to ensure your equipment stays up and running.

Our commitment to exceptional customer service and timely delivery make us the ideal choice for all your IT hardware needs. Choose Enterasource for a hassle-free experience and the highest quality product on the market.

Dell Networking S4048T-ON 10GbE Switch
Manufacturer:
Dell
Condition:
Refurbished
Availability:
Ships in 5-7 Business Days
Too many options? We are happy to help you configure.
Ask a question
Requires 2 for proper configuration
Qty:
Requires 2 for proper configuration
Qty:

Description

The Dell Networking S4048T-ON is a 1U open-networking top-of-rack switch with 48x 10GBASE-T, 6x 40GbE QSFP+. It moves 1.44 Tbps full-duplex through a non-blocking cut-through fabric at 1080 Mpps with 2.8 us port-to-port latency.

Where the S4048T-ON sits in a data center

This is the copper member of its family. The S4048T-ON terminates 48 ports of 10GBASE-T on RJ45, so it serves racks of servers with onboard 10GBASE-T LOM or add-in NICs over Cat6a and Cat7 structured cabling instead of fibre or twinax. That matters in two situations: brownfield racks already cabled for copper, and mixed racks where run lengths approach 100 m and direct-attach copper cannot reach. The trade is latency and power - 10GBASE-T PHYs add both, which is why this model reports 2.8 us where its SFP+ sibling reports well under a microsecond, and why it draws more at the wall.

Deployed as a top-of-rack leaf, the fixed ports face the servers and the 6x 40GbE QSFP+ face the spine. In a two-tier leaf-spine build a pair of these switches sits in each rack running VLT, so each server can dual-home with LACP into two physically separate chassis and survive the loss of either one. VLT is the reason there is no stacking port on this switch: Dell's S-Series uses multi-chassis link aggregation rather than a stack ring, which means the two peers keep independent control planes and can be upgraded one at a time without dropping the rack.

Port layout and breakout math

Each of the 6 QSFP+ uplinks breaks out to 4x 10GbE with a breakout cable, so 48 fixed 10GBASE-T ports plus 24 broken-out SFP+ ports reach the 72-port 10GbE maximum Dell publishes for this switch.

Fixed ports: 48x 10GBASE-T supporting 100M/1G/10G, 6x 40 Gigabit Ethernet QSFP+. That breakout capability is the reason a 48-port switch is worth quoting against a larger chassis - the uplinks are not dead weight if you do not need them at their native speed, they convert into usable access ports with a passive breakout cable.

Airflow: standard and reverse builds

This listing covers both airflow builds of the S4048T-ON. Select the direction under the Airflow option: air direction is set by the power supplies and fan modules physically fitted, so it is chosen when the unit is built rather than switched afterwards. Power supplies and fans must both face the same way - a mismatched pair raises the switch's incompatible-airflow alarm.

Standard airflow (I/O to PSU)

The normal-airflow (NA) build, also written I/O-to-PSU or front-to-back. Air enters at the port face and exhausts at the power-supply end. Fit it when the switch is mounted with its ports facing the hot aisle, which is the conventional orientation in a cold-aisle-containment room where servers also pull from the front.

Airflow is fixed by the power supplies and fan modules that are physically installed, and the two must match each other. If your rack presents the switch ports to the cold aisle, you want the Reverse Airflow option above - converting a chassis in the field means swapping both the PSUs and the fan modules, not flipping a setting.

Reverse airflow (PSU to I/O)

The reverse-airflow (RA) build, sometimes written PSU-to-I/O or back-to-front. Air is drawn in at the power-supply end of the chassis and exhausted out of the port face. Fit it when the switch is mounted with its ports facing the cold aisle - the common arrangement when you want to patch from the front of the rack and keep cabling out of the hot aisle.

Airflow is not a setting. It is determined by the physical power supplies and fan modules installed, and the two must agree: a reverse-airflow chassis needs reverse-airflow PSUs and reverse-airflow fans. Mixing directions makes the switch raise an incompatible-airflow alarm and leaves a stalled thermal path. If your rack is laid out the other way - ports on the hot aisle - order the Normal Airflow option above of trying to reverse this one in the field.

Operating system and licensing on a used S4048T-ON

Dell Networking OS9 (FTOS); ONIE-enabled for OS10 or third-party NOS. Because the platform is ONIE-based, the operating system is not welded to the hardware: the switch boots into the ONIE installer and pulls whichever network operating system you point it at. That is the whole premise of Dell's open-networking line and it is what makes these switches practical on the secondary market.

Be precise about which OS you are planning around, because the scale numbers differ. The figures Dell publishes for this chassis - 160K MAC addresses, 128K IPv4 routes - are the OS9 numbers. OS9 (the FTOS lineage) is the software this generation shipped with. OS10 also runs on this hardware and third-party NOS options such as SONiC and Cumulus have historically been supported on the platform.

What a used unit does not carry is an active Dell software entitlement or support contract. Licensing and OS entitlement are handled directly between you and Dell (or the NOS vendor) and are not transferred by the sale of hardware. Plan for that in your build: if you need a licensed, vendor-supported OS10 image, source the entitlement separately. If you are running an open NOS, this is a non-issue and is one of the main reasons buyers choose ONIE hardware secondhand. We describe the hardware condition and back the hardware with a warranty; we make no representation about Dell software support status.

Choosing between the S4000-series models

The suffix letters are the fastest way to read this family. F means SFP+ fibre and direct-attach ports. T means 10GBASE-T copper on RJ45. U means unified ports that run either Ethernet or Fibre Channel. The two-digit number before the letter is the fixed port count - 12, 28, 40 or 48.

The generation gap matters as much as the letter. The S4048-ON and S4048T-ON are the 2014 open-networking wave: 1.44 Tbps of fabric, 1080 Mpps, six 40GbE uplinks and no 100GbE anywhere. The S4100-ON models - S4148F-ON, S4148T-ON, S4128F-ON and S4128T-ON - are the 2017 refresh on Broadcom Maverick silicon: up to 1.76 Tbps, 1320 Mpps, and QSFP28 uplinks that give you real 100GbE and multi-rate 25/50GbE breakout. If you are buying to sit under a 100GbE spine, the S4100 generation is the one that connects to it natively; the S4048 generation tops out at 40GbE.

Above both sits the S4248FB-ON from the S4200-ON series, which trades a few access ports for six QSFP28 uplinks and a much larger control-plane complex - the configuration usually chosen for border-leaf and WAN-edge duty rather than plain server access.

Condition, testing and warranty

Every S4048T-ON we ship is refurbished enterprise hardware: inspected, cleaned, powered up and functionally tested before it leaves the building, and supplied with warranty coverage. Configure the power supplies, fan modules, rail kit, console cable and optics you need above and the unit is built to that specification rather than shipped as a bare chassis. If you are matching an existing pair for a VLT peer, tell us the airflow direction and PSU part numbers you already run and we will match them.

Specifications

MPNS4048T-ON
ManufacturerDell
Product LinePowerSwitch S-Series
ConditionRefurbished
Ports48x 10GBASE-T supporting 100M/1G/10G, 6x 40 Gigabit Ethernet QSFP+
Number of Ports48
Port Speed10G
Uplinks / Downlinks6x 40GbE QSFP+
Interface10GBASE-T copper (RJ45) with 100M/1G/10G autonegotiation
Connector TypeRJ45 (10GBASE-T) / QSFP+
Data Rate10 Gbps
PoENo
Throughput1.44 Tbps full-duplex
Forwarding Performance1080 Mpps
System Capacity1.44 Tbps full-duplex non-blocking, cut-through switching fabric
Memory (Shared)4 GB CPU memory
Installed Flash Memory8 GB SSD module
Operating SystemDell Networking OS9 (FTOS); ONIE-enabled for OS10 or third-party NOS
RoutingFull Layer 2 and Layer 3 switching and routing (OSPF, BGP, PBR, VRF-lite, VLT)
MAC Addresses160K (OS9)
Number of VLANs4K Layer 2 VLANs
IPv4 Scale128K (OS9) IPv4 routes, 128K (OS9) ARP entries
IPv6 Scale64K (OS9) IPv6 routes, 64K (OS9) IPv6 hosts
QoS Queues8 data queues, 12 control queues
Remote Management ProtocolSNMPv1/v2c/v3, SSHv2, Telnet, FTP/TFTP, RADIUS, TACACS+, sFlow, LLDP/LLDP-MED
StackableNo - VLT (Virtual Link Trunking) is used for multi-chassis redundancy instead of stacking
Rack Units1U
Dimensions1.71 x 17.09 x 18.11 in (H x W x D)
Height1.71 in (4.35 cm)
Width17.09 in (43.4 cm)
Depth18.11 in (46 cm)
Weight23 lbs
Power Supply Type2 hot-swappable redundant power supplies
PSU Wattage550W
Power Input100-240 VAC 50/60 Hz (DC: -40.5V to -60V)
Max Power Consumption460W
Redundant Power SupplyYes - dual hot-swappable power supplies
Power Supply Redundancy1+1 redundant
Integrated Power Supply (Not Removable)No - power supplies are field-replaceable modules
Acoustic Output65 dB at 77F (25C)
Airflow DirectionNormal airflow (I/O side to PSU side) - exhausts away from the port face
CoolingHot-swappable redundant fan modules
Link Aggregation16 links per group, 128 groups
MSTP Instances64 instances
Management Ports1 RJ45 console/management port (RS232), 1 USB 2.0 Type-A, 1 micro-USB 2.0 Type-B serial console port, 1x 8 GB SSD module
Maximum 10GbE Port Density72 (with 40GbE-to-4x10GbE breakout cables)
Maximum 40GbE Port Density6
Maximum Thermal Output1568 BTU/h
Multicast Hosts8K
Open NetworkingONIE pre-installed - supports Dell OS10, OS9 and third-party network operating systems
Operating Temperature32F to 113F (0C to 45C)
Packet Buffer Memory16 MB
Port-to-Port Latency2.8 us
Rack Mounting1U, 19-inch rack, universal rail kit (JKTTN / 5RN1M / N243X)
Typical Operating Power338W
VRF-lite Instances511 instances

Technical Specs

Part TypeEthernet Switch
MPNS4048T-ON
ManufacturerDell
ConditionRefurbished
Product LinePowerSwitch S-Series
Interface10GBASE-T copper (RJ45) with 100M/1G/10G autonegotiation
Rack Units1U
Number of Ports48
Port Specs48x 10GBASE-T supporting 100M/1G/10G, 6x 40 Gigabit Ethernet QSFP+
Port Speed10G
PoENo
Uplinks / Downlinks6x 40GbE QSFP+
Memory4 GB CPU memory
Installed Flash Memory8 GB SSD module
Power Supply Type2 hot-swappable redundant power supplies
PSU Wattage550W
Redundant Power SupplyYes - dual hot-swappable power supplies
Forwarding Performance1080 Mpps
Throughput1.44 Tbps full-duplex
System Capacity1.44 Tbps full-duplex non-blocking, cut-through switching fabric
RoutingFull Layer 2 and Layer 3 switching and routing (OSPF, BGP, PBR, VRF-lite, VLT)
Data Rate10 Gbps
Connector TypeRJ45 (10GBASE-T) / QSFP+
Operating SystemDell Networking OS9 (FTOS); ONIE-enabled for OS10 or third-party NOS
Quality-of-Service (QoS) queues/port8 data queues, 12 control queues
MAC Addresses160K (OS9)
IPv4 unicast/multicast routes128K (OS9) IPv4 routes, 128K (OS9) ARP entries
IPv6 unicast/multicast routes64K (OS9) IPv6 routes, 64K (OS9) IPv6 hosts
Number of VLANs4K Layer 2 VLANs
Remote Management ProtocolSNMPv1/v2c/v3, SSHv2, Telnet, FTP/TFTP, RADIUS, TACACS+, sFlow, LLDP/LLDP-MED
Dimensions1.71 x 17.09 x 18.11 in (H x W x D)
Width17.09 in (43.4 cm)
Depth18.11 in (46 cm)
Height1.71 in (4.35 cm)
Weight23 lbs
Integrated Power Supply (Not Removable)No - power supplies are field-replaceable modules
Power100-240 VAC 50/60 Hz (DC: -40.5V to -60V)
Max Power Consumption (Watts)460W
Power Supply Redundancy1+1 redundant
StackableNo - VLT (Virtual Link Trunking) is used for multi-chassis redundancy instead of stacking
Write Your Own Review
You're reviewing:Dell Networking S4048T-ON 10GbE Switch
Your Rating
Product added to your quote
© 2026 Enterasource, LLC. All Rights Reserved.