The Dell Networking S4248FB-ON is a 1U open-networking top-of-rack switch with 40x 1/10GbE SFP+, 2x 40GbE QSFP+, 6x 100GbE QSFP28. It carries 1.08 Tbps aggregate line-rate port bandwidth (40 x 10G + 2 x 40G + 6 x 100G) across its fixed and uplink ports.
Where the S4248FB-ON sits in a data center
This is the fibre and direct-attach member of its family. The S4248FB-ON presents 40 ports of SFP+, which take either optical transceivers or passive twinax DAC cables. Inside a rack, DAC is the normal choice - it is cheaper than optics, draws almost no power and keeps port-to-port latency at None. Optics take over for cross-row and cross-room runs.
Deployed as a top-of-rack leaf, the fixed ports face the servers and the 2x 40GbE QSFP+ and 6x 100GbE QSFP28 face the spine. In a two-tier leaf-spine build a pair of these switches sits in each rack running VLT, so each server can dual-home with LACP into two physically separate chassis and survive the loss of either one. VLT is the reason there is no stacking port on this switch: Dell's S-Series uses multi-chassis link aggregation rather than a stack ring, which means the two peers keep independent control planes and can be upgraded one at a time without dropping the rack.
Port layout and breakout math
40 fixed SFP+ ports, plus 4x1/10GbE breakout on each of the 2 QSFP+ ports (8) and 4x25/10GbE breakout on each of the 6 QSFP28 ports (24), gives 72 usable 10GbE interfaces.
Fixed ports: 40x 1/10GbE SFP+, 2x QSFP+ (40GbE or 4x1/10GbE), 6x QSFP28 (100/40GbE, 4x25/10GbE or 2x50GbE). That breakout capability is the reason a 40-port switch is worth quoting against a larger chassis - the uplinks are not dead weight if you do not need them at their native speed, they convert into usable access ports with a passive breakout cable.
Airflow: which direction this unit blows
This is the normal-airflow (NA) build, also written I/O-to-PSU or front-to-back. Air enters at the port face and exhausts at the power-supply end. Fit it when the switch is mounted with its ports facing the hot aisle, which is the conventional orientation in a cold-aisle-containment room where servers also pull from the front.
Airflow is fixed by the power supplies and fan modules that are physically installed, and the two must match each other. If your rack presents the switch ports to the cold aisle, you want the reverse-airflow variant instead - converting a chassis in the field means swapping both the PSUs and the fan modules, not flipping a setting.
Operating system and licensing on a used S4248FB-ON
ONIE pre-installed; Dell EMC Networking OS10 Enterprise Edition or a third-party NOS. Because the platform is ONIE-based, the operating system is not welded to the hardware: the switch boots into the ONIE installer and pulls whichever network operating system you point it at. That is the whole premise of Dell's open-networking line and it is what makes these switches practical on the secondary market.
What is unusual about this chassis is the size of the control-plane complex behind the forwarding silicon. Dell's installation guide documents two build variants: a TCAM SKU with 32 GB of DDR3 and a 64 GB iSLC mSATA SSD, and a non-TCAM SKU with 8 GB and 16 GB. Even the smaller of those is generous for a fixed-format top-of-rack switch, and the larger one is the reason this model gets chosen for border-leaf and WAN-edge roles where the routing table and the control-plane workload are the constraint rather than raw port count. Check which variant you are quoting if your design depends on large routing tables.
What a used unit does not carry is an active Dell software entitlement or support contract. Licensing and OS entitlement are handled directly between you and Dell (or the NOS vendor) and are not transferred by the sale of hardware. Plan for that in your build: if you need a licensed, vendor-supported OS10 image, source the entitlement separately. If you are running an open NOS, this is a non-issue and is one of the main reasons buyers choose ONIE hardware secondhand. We describe the hardware condition and back the hardware with a warranty; we make no representation about Dell software support status.
Choosing between the S4000-series models
The suffix letters are the fastest way to read this family. F means SFP+ fibre and direct-attach ports. T means 10GBASE-T copper on RJ45. U means unified ports that run either Ethernet or Fibre Channel. The two-digit number before the letter is the fixed port count - 12, 28, 40 or 48.
The generation gap matters as much as the letter. The S4048-ON and S4048T-ON are the 2014 open-networking wave: 1.44 Tbps of fabric, 1080 Mpps, six 40GbE uplinks and no 100GbE anywhere. The S4100-ON models - S4148F-ON, S4148T-ON, S4128F-ON and S4128T-ON - are the 2017 refresh on Broadcom Maverick silicon: up to 1.76 Tbps, 1320 Mpps, and QSFP28 uplinks that give you real 100GbE and multi-rate 25/50GbE breakout. If you are buying to sit under a 100GbE spine, the S4100 generation is the one that connects to it natively; the S4048 generation tops out at 40GbE.
Above both sits the S4248FB-ON from the S4200-ON series, which trades a few access ports for six QSFP28 uplinks and a much larger control-plane complex - the configuration usually chosen for border-leaf and WAN-edge duty rather than plain server access.
Condition, testing and warranty
Every S4248FB-ON we ship is refurbished enterprise hardware: inspected, cleaned, powered up and functionally tested before it leaves the building, and supplied with warranty coverage. Configure the power supplies, fan modules, rail kit, console cable and optics you need above and the unit is built to that specification rather than shipped as a bare chassis. If you are matching an existing pair for a VLT peer, tell us the airflow direction and PSU part numbers you already run and we will match them.
Specifications
| MPN | S4248FB-ON |
|---|---|
| Manufacturer | Dell |
| Product Line | PowerSwitch S-Series |
| Condition | Refurbished |
| Ports | 40x 1/10GbE SFP+, 2x QSFP+ (40GbE or 4x1/10GbE), 6x QSFP28 (100/40GbE, 4x25/10GbE or 2x50GbE) |
| Number of Ports | 40 |
| Port Speed | 10G SFP+ |
| Uplinks / Downlinks | 2x 40GbE QSFP+ and 6x 100GbE QSFP28 |
| Interface | 1/10 Gigabit Ethernet SFP+ (fibre / direct-attach copper) |
| Connector Type | SFP+ / QSFP+ / QSFP28 (fibre or DAC) |
| Data Rate | 1/10 Gbps |
| PoE | No |
| Memory (Shared) | 32 GB DDR3 (TCAM SKU) / 8 GB DDR3 (non-TCAM SKU) |
| Installed Flash Memory | 64 GB iSLC mSATA SSD (TCAM SKU) / 16 GB iSLC mSATA SSD (non-TCAM SKU) |
| Operating System | ONIE pre-installed; Dell EMC Networking OS10 Enterprise Edition or a third-party NOS |
| Routing | Full Layer 2 and Layer 3 switching and routing (OSPF, BGP, PBR, VRF-lite, VLT) |
| Remote Management Protocol | SNMPv1/v2c/v3, SSHv2, Telnet, FTP/TFTP, RADIUS, TACACS+, sFlow, LLDP/LLDP-MED |
| Stackable | No - VLT (Virtual Link Trunking) is used for multi-chassis redundancy instead of stacking |
| Rack Units | 1U |
| Dimensions | 1.72 x 17.1 x 18.2 in (H x W x D) |
| Height | 1.72 in (44 mm) |
| Width | 17.1 in (434 mm) |
| Depth | 18.2 in (462 mm) |
| Weight | 22 lbs |
| Power Supply Type | 2 hot-swappable redundant power supplies |
| Power Input | 100-240 VAC 50/60 Hz (DC: -40.5V to -60V, 15A max) |
| Max Power Consumption | 600W |
| Redundant Power Supply | Yes - dual hot-swappable power supplies |
| Power Supply Redundancy | 1+1 redundant |
| Integrated Power Supply (Not Removable) | No - power supplies are field-replaceable modules |
| Aggregate Port Bandwidth | 1.08 Tbps aggregate line-rate port bandwidth (40x10G + 2x40G + 6x100G) |
| Airflow Direction | Normal airflow (I/O side to PSU side) - exhausts away from the port face |
| Cooling | 5 fan subsystems |
| Management Ports | 1 RJ-45 console port, 1 USB Type-A 2.0 port, Ethernet management port |
| Maximum 100GbE Port Density | 6 |
| Maximum 10GbE Port Density | 72 (40 fixed SFP+ plus 8 from QSFP+ breakout and 24 from QSFP28 breakout) |
| Maximum 40GbE Port Density | 8 |
| Maximum Thermal Output | 2047 BTU/h |
| Open Networking | ONIE pre-installed - supports Dell OS10, OS9 and third-party network operating systems |
| Operating Temperature | 32F to 113F (0C to 45C) continuously; 23F to 113F (-5C to 45C) short term |
| Rack Mounting | 1U, 19-inch rack, universal rail kit (JKTTN / 5RN1M / N243X) |
| Typical Operating Power | 300W |